Eazi-Breed CIDR Cattle

Eazi-Breed CIDR Cattle Devices contain the natural hormone progesterone. Intra-vaginally placed CIDR’s release progesterone at a controlled rate into the blood stream.
Eazi-Breed CIDR Cattle
$224.85
Eazi-Breed CIDR Cattle Devices contain the natural hormone progesterone. Intra-vaginally placed CIDR’s release progesterone at a controlled rate into the blood stream.
Breeding programs using the CIDR Cattle Device can:
• Tighten oestrus synchronisation so animals come into oestrus in a narrow time period
• Provide an opportunity to induce a fertile oestrus in non-cycling cows
• Hasten the onset of cyclicity in maiden heifers
• Treat cystic ovarian disease
• Prepare donor recipient cattle for embryo transfer programs.
•
Using CIDR Cattle Devices can result in:
• More pregnancies
• More compact calving season
• More even line of calves
• Less involuntary culling of non-pregnant cows
• Better use of time and labour during breeding, pregnancy testing and calving
• Tighter calving intervals, with more calves born during a cow’s lifetime
• Easier and more accurate heat detection, or the option of no heat detection
• Enhanced use of artificial insemination (AI) or specialist programs such as ET, with
• Greater genetic gain and higher value calves
• Ability to schedule heifers to calve before older cows, so heifers can get extra attention
• Easier customised matings – including the use of calving-ease sires – because AI is more feasible
• Confirmed breeding and calving dates – not always possible with natural service
• A more profitable herd.
WITHHOLDING PERIODS (WHP)
MEAT (Cattle): Zero (0) days.
MILK (Cattle): Zero (0) days.
Wear protective gloves when handling the devices.
Insertion
• Dip the device applicator in a non-irritating antiseptic solution.
• Place one device into the applicator so the wings are folded and only the tips of these wings protrude from the front of the applicator.
• Dip the front portion of the loaded applicator into a suitable veterinary obstetrical lubricant.
• Lift the tail of the animal and wipe the vulva lips clean with disposable tissue.
• With the tail lifted, insert the loaded applicator, sloping slightly upwards, through the vulva and then forward, without forcing, into the forward portion of the vagina.
• Release the removal tail, grasp the handle of the plunger and ease back the barrel of the applicator towards the handle.
• With the device correctly placed with the wings opened in the front portion of the vagina, only the removal tail should be hanging from the vulva.
• Repeat STEP 1 before re-using the applicator.
Removal
• Withdraw each device by pulling on the removal tail.
• Always remove at least 24 hours before slaughter.


